Industrial Manuals, Standards and Codes I’ve Consulted

 


When doing calculations, designing, and/or on-site work, we have to figure out which standard and code (federal, state, local) we will follow.  

EPA and Permits

On-site Measurement

Airborne Contaminants

Industrial Ventilation

  • Industrial Ventilation Manual by ACGIH (for Design and Operation & Maintenance)
  • OSHA Technical Manual (OTM) Section III, Chapter 3: Ventilation Investigation
  • ANSI/AIHA Z9, Ventilation Standards
  • SMACNA (The Sheet Metal and Air Conditioning Contractors' National Association)
  • NEBB: Procedural Standards or Guides for Air Balancing

Equipment Testing

  • ANSI/ASHRAE Standard 199: testing process to test how well dust collectors perform in real-world conditions

Pressure Vessel / Pressure Piping

  • ASME pressure vessel code
  • ASME B31.1: Power piping
  • ASME B31.3: Process Piping
  • ASME B16.5 Pipe Flanges & Flanged Fittings

FRP (Fiberglass Reinforced Polymer)

  • ASME RTP-1

Plastics

  • ISO 15494: Plastics Piping Systems for Industrial Applications (PB, PE, PE-RT, PE-X, PP)

Demolition

  • 29 CFR 1926.850(a) and OSHA Technical Manual (OTM) Section V: Chapter 1, Demolition

Others

  • OSHA and NIOSH: Small Business Safety and Health Handbook
  • The FDA Food Safety Modernization Act (FSMA)
  • ASCE 7: Minimum Design Loads for Buildings and Other Structures

Fire and Explosion Protection

  • FM Global Property Loss Prevention Data Sheets – 7-73 (Dust Collectors and Collecting Systems) & 7-76 (Prevention and Mitigation of Combustible Dust Explosion and Fire)
  • OSHA Technical Manual – Section IV, Chapter 6, Combustible Dusts
  • NFPA codes
    • NFPA 1: Fire Code
    • NFPA 13: Standard for the Installation of Sprinkler Systems
    • NFPA 25: Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems
    • NFPA 36: Standard for Solvent Extraction Plants
    • NFPA 51B, Standard for Fire Prevention During Welding, Cutting, and Other Hot Work
    • NFPA 61: Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities
    • NFPA 68: Standard on Explosion Protection by Deflagration Venting
    • NFPA 69: Standard on Explosion Prevention Systems
    • NFPA 70: National Electrical Code (NEC)
    • NFPA 77: Recommended Practice on Static Electricity
    • NFPA 85: Boiler and Combustion Systems Hazards Code
    • NFPA 86: Standard for Ovens and Furnaces
    • NFPA 90A: Standard for the Installation of Air-Conditioning and Ventilating Systems
    • NFPA 91: Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Particulate Solids
    • NFPA 92: Standard for Smoke Control Systems
    • NFPA 221: Standard for High Challenge Fire Walls, Fire Walls, and Fire Barrier Walls
    • NFPA 484: Standard for Combustible Metals
    • NFPA 651: Standard for the Machining and Finishing of Aluminum and the Production and Handling of Aluminum Powders
    • NFPA 652 for DHA (Dust Hazards Analysis)
    • NFPA 654: Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids
    • NFPA 664: Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities
    • NFPA 1192: Standard on Recreational Vehicles

Comments

Popular posts from this blog

What you have to know when applying blast gate damper

  Introduction A damper is a device that adjusts the volume of airflow passing through the outlet, inlet or duct. By proper adjustment of all dampers in a system, a desired distribution of airflows in all the branches can be obtained, while minimizing the total airflow of the system to save energy— this is also termed air balancing. The most common dampers used in industrial ventilation and dust collection systems to balance airflows are slide gate dampers (The slide gate, also called “blast gate or cut-off” damper). In a slide gate damper (see Figure 1 of a straight flat slide gate damper), the slide is inserted perpendicular to the flow. Figure 1 A sample of straight flat slide gate damper As the gate is sliding into the duct, it will add resistance to the airflow and consequently reduce the volume of airflow, while increasing airflows in all other branches. Withdrawing the gate has the reverse effect on that branch and all the others in a system. Interaction between a fan ...

Push-pull ventilation system for open surface tank saves air flow

  Three sections in this blog: Push-pull ventilation system and its advantages Disadvantages of general ventilation and side exhaust systems Methods to design a push-pull ventilation system Push-pull ventilation system and its advantages Open surface tanks used in industrial processes often need ventilating to remove harmful pollutants (vapors, fumes or aerosols) from the working environment. One method of removing pollutants is the so-called side push-pull ventilation system, in which a jet of air is blown (or pushed) from one side of the tank and collected (or pulled) by an exhaust hood on the opposite parallel side. This system is particularly useful for large tanks where access requirements preclude the use of an overhead canopy, and the size of the tank makes side (or rim) exhaust systems prohibitively expensive. Most agree that a push-pull ventilation system can yield air savings of up to 50% compared to a side suction only hood. An illustration of a push-pull system for an o...